RYDR cutout-mounted single-phase recloser for branch taps, transformers and boundary points. This single phase recloser restores transient faults automatically, reducing repeated fuse replacement without changing the cutout mounting setup.
The same cutout-mounted body covers three voltage classes. Match insulation level, rated current, reclose settings and protection curve before preparing drawings, labels or export documents.

Use this class when the RFQ calls for 36 kV equipment with 170 kV BIL, 6.3 kA interruption and 40 / 100 / 200 A current options.

The D820-29/40 report gives a 27 kV, 40 A test record while the catalog table keeps 100 A and 200 A options visible for RFQ matching.

Use this class when the project needs single-phase reclosing, hot-stick service and visual isolation without specifying a full feeder recloser package.
The assembly combines vacuum interruption, magnetic actuation, current sensing, RF communication and hot-stick operation inside a cutout-mounted package for branch-line protection upgrades.
Mounts directly on an existing fuse insulator, so the buyer can evaluate it as a cutout fuse upgrade rather than a full feeder recloser package.
ANSI 50/51 and ANSI 79 logic supports trip and reclose behavior, with up to 3 recloses and adjustable reset timing listed in the product data.
Hot-stick open and close operation plus pull-down visual isolation support field maintenance after local safety procedures are confirmed.
RF communication, event logs and PC software settings should match the protection curve and remote operation needs before quotation.
Check the protection setup here: vacuum interruption, ANSI 50/51 trip logic, ANSI 79 reclosing, low-current sensing and local or wireless operation.
Vacuum interrupting medium and magnetic mechanism let the device trip and close inside a compact cutout-mounted structure.
Single-phase overcurrent, reclosing and instant, delayed or time-inverse trips are supported with IEC and ANSI curves.
Operation starts above 1 A for the 40 A model and above 2 A for 100 A / 200 A models, with class 0.5 / 5P sensing and backup battery support.
SingleTool software, RF communication, WiFi operation and event logs help confirm settings before installation and review operation after fault events.
The best-fit points are branch taps, transformer protection and customer boundary supply where transient faults should not create long outages or repeated site visits.

For single-phase taps where temporary faults should be handled locally without sending crews for every fuse operation.

For cutout-fuse replacement around distribution transformers, especially where outage duration and O&M visits are recurring concerns.

For customer boundary or project entrance points where testing, packaging, nameplate, controller and document details must be locked before shipment.
The D820-29/40 report records dimensions, operating time, CT accuracy, minimum tripping current, time-current checks, insulation tests and IEC 62271-111:2019 qualification language.
The report identifies the tested cutout-mounted recloser designation and rated values.
Structural inspection, overall dimensions, nameplate information and packaging inspection are listed with PASS results.
Examples include 7.22 ms opening time, 25.15 ms closing time, 0.57 ms contact bounce and 6.1 V battery voltage.
The report includes insulation resistance, partial discharge and power-frequency withstand tests with PASS conclusions.
PC software remote open/close, fault reset, ANSI 79 reclosing and protection alarm exit checks are included.
The conclusion states compliance with IEC 62271-111:2019 for 38 kV and below high-voltage AC automatic reclosers.

Use the packing and report set to confirm nameplate, factory test record, shipment quantity and export-document details.

Batch supply is the right context for confirming drawings, labels, controller settings and inspection documents before production release.
A cutout single phase recloser is a single-phase automatic recloser that mounts at a fuse cutout position. It trips on overcurrent faults, recloses after a set interval and keeps a visible isolation gap for field service.
It fits cutout-mounted protection points where automatic trip and reclose behavior is needed. For fuse-only protection, compare the Smart Drop-Out Fuse option. Final suitability depends on voltage, current, fault level and utility practice.
No. This page is for a single-phase cutout-mounted product. For feeder-level three-phase automation, compare the Automatic Vacuum Circuit Recloser.
Send voltage class, rated current option, installation photos or drawings, protection setting expectations, communication needs, quantity, destination and required test or inspection documents.
Product documents show direct mounting on a fuse insulator, live-line installation possibility, hot-stick operation and visual isolation distance. Project procedures still need to follow local utility safety rules.
Indicative FOB equipment range for early budgeting. Final quote depends on rating class, controller package, quantity, destination and utility standard.
Use the line position to confirm whether this page is the right product family.
Voltage class, current class, cutout arrangement, protection settings and routine test request.
Send drawings, photos, electrical ratings and export requirements through the RFQ form.
Include voltage class, current option, branch role, installation photos, curve or reclose settings, communication needs, quantity, labels and required test/export documents. For company background, see About XIYA POWER.