Pole-mounted SF6 LBS

Pole-Mounted SF6 Load Break Switch (IACT)

The main product is an outdoor SF6 insulated load break switch for overhead feeder load switching, sectionalizing, loop points and transformer circuit control. Add the LBS controller only when the project needs sensing, local operation, event records or SCADA communication.

Products/Smart Grid/Pole-Mounted SF6 Load Break Switch (IACT)
12 / 24 / 36 kVLRFW source tables separate the visible switch-body voltage classes.
400 / 630 ABase rated-current options for the displayed LRFW switch body.
Optional controllerThe LBS cabinet is an automation layer, not the primary switch body.
Specification

SF6 Load Break Switch Ratings Before Controller Selection.

LRFW source data defines the visible 12 / 24 / 36 kV switch-body table. Confirm the selected series before nameplate or drawing release because PGS/RPS files describe a separate family with different current, short-time, IP and standard references.

Pole-mounted SF6 load breaker switch product view with sealed tank and rubber bushings
LRFW 12 kV source data

12 kV feeder load switching class.

For 12 kV medium-voltage feeders requiring load current switching, line sectionalizing or transformer circuit control with a controller-ready pole switch body.

Parameter
12 kV data
Rated voltage
12 kV
Rated frequency
50 / 60 Hz
Rated current
400 / 630 A
Rated short-circuit withstand / breaking current
12.5 kA
Rated short-circuit making current
31.5 kA peak
Rated peak withstand current
31.5 kA
Rated short-circuit time
1 second
Power operating time
<2 seconds close / open
Power-frequency withstand voltage
28 / 32 kV for 1 minute
Lightning impulse withstand voltage
76 / 85 kV peak
Pole-mounted SF6 load breaker switch product view for 24 kV class reference
LRFW 24 kV source data

24 kV distribution switching class.

This class fits feeder sectionalizing, loop switching and transformer circuit control projects where the application voltage level is 24 kV.

Parameter
24 kV data
Rated voltage
24 kV
Rated frequency
50 / 60 Hz
Rated current
400 / 630 A
Rated short-circuit withstand / breaking current
12.5 kA
Rated short-circuit making current
31.5 kA peak
Rated peak withstand current
31.5 kA
Rated short-circuit time
1 second
Power operating time
<2 seconds close / open
Power-frequency withstand voltage
50 / 60 kV for 1 minute
Lightning impulse withstand voltage
125 / 145 kV peak
Pole-mounted SF6 load breaker switch product view for 36 kV class reference
LRFW 36 kV source data

36 kV upper distribution class.

For feeder voltage and insulation levels requiring the 36 kV application group. Confirm installation space and terminal dimensions before final drawing.

Parameter
36 kV data
Rated voltage
36 kV
Rated frequency
50 / 60 Hz
Rated current
400 / 630 A
Rated short-circuit withstand / breaking current
12.5 kA
Rated short-circuit making current
31.5 kA peak
Rated peak withstand current
31.5 kA
Rated short-circuit time
1 second
Power operating time
<2 seconds close / open
Power-frequency withstand voltage
70 / 80 kV for 1 minute
Lightning impulse withstand voltage
170 / 190 kV peak
Shared values

These shared values are LRFW source values, not a merged PGS/RPS table: 5000 mechanical operations, 400 rated full-load operations, IP65 protection level, SF6 gas as both arc-extinction and insulation medium, and SF6 gas yearly leak rate <=0.5%. Service conditions include altitude <=3000 m, -40 deg C to +50 deg C air temperature, maximum wind speed <=34 m/s and pollution grade III / IV. The separate RPS/PGS catalog family lists IEC 62271-103, 400 / 630 / 800 / 1250 A, 20 kA / 4 s, IP67 and suspended or horizontal mounting, so do not merge those values into this LRFW table.

Structure

Switch Body, Controller Package and RFQ Boundary.

The buyer selects the outdoor SF6 LBS body first. Controller cabinet, motor wiring and communication interface are added after body rating, mounting method and sensing plan are fixed.

Pole-mounted SF6 load break switch body product photo

What the switch body includes.

The LRFW structure sheet identifies the outdoor switch body as the high-voltage equipment: lift handle, carrying handle, rubber bushing, manual operation handle, contact position indicator, support frame, grounding device, locking device, gas pressure relief, electric mechanism, SF6 pressure gauge and filling valve.

Switch bodySF6 insulated tank, bushings, line terminals, operating mechanism, pressure gauge and open/close indication.
Mounting relationshipSingle-pole drawings show anchor ears, assembly frame, lift handle, hole, nameplate and controller box position.
Optional controllerLBS cabinet for phase and ground current sensing, three-phase voltage sensing, alarms, local operation and SCADA connection.
RFQ boundaryQuote the switch body first. Add controller, CT/VT sensing, motor wiring and communication only when the project needs them.
Controls

LBS Controller Functions for Sensing, Operation and SCADA.

The LBS controller supports sensing, motorized operation, alarms, records and communication after the switch body is selected. It does not make this device an automatic vacuum circuit recloser for fault-current interruption.

Current and voltage sensing

The controller provides phase and ground current sensing, three-phase voltage sensing, and can compute power, energy, power factor and power flow direction.

Phase currentGround current3-phase voltage

Front panel and software setup

Settings can be programmed from the front panel, PC configuration software or web browser through temporary Ethernet or USB access.

Front panelPC toolWeb browser

SCADA and device interface

The manual references RS-232, Ethernet and RS-485 ports for SCADA or interconnection to other devices.

RS-232EthernetRS-485

Event and analysis tools

The controller tools include event recording, data profiler, application one-line diagram, oscillography and time-current curve functions.

Event recordOscillographyTCC
SF6 load break switch shown with optional LBS controller cabinet and cable accessories

Switch body plus controller package

Package scope: switch body, controller cabinet, cable accessories and motorized operation.

Open LBS controller cabinet with front panel and cable connectors

Controller cabinet body

Select the cabinet after the switch rating, mounting method, sensor requirement, motor wiring and communication interface are fixed.

Applications

Feeder Switching Path and Optional Controller Signals.

The topology separates the main feeder load-current path from optional sensing, command and communication paths.

Principle topology at the SF6 load switch pointPower path + optional controller
Pole-mounted SF6 load break switch topology showing feeder source SF6 LBS body downstream load endpoints and optional LBS controller paths for sensing command SCADA local setup and power
Power path: feeder source to SF6 LBS body, then to feeder sectionalizing, loop/tie or transformer circuit endpoints. Sensing path: phase current, source-side voltage, load-side voltage and switch position feed the controller. Optional control path: open/close command, front panel, PC setup, Ethernet, USB, RS-232 or RS-485 to SCADA / DA.
Endpoint
Path type
RFQ implication
Feeder source to downstream endpoint
Load current path
Confirm voltage class, rated current, short-time requirement and line terminal or cable outlet style.
Current / voltage / position signals
Sensing path
Confirm CT ratio, source-side and load-side voltage sensing, open/close status and alarm requirement.
Controller to operator or SCADA
Command and communication path
Confirm local front panel, PC tool, Ethernet, USB, RS-232, RS-485 or SCADA / DA interface.
Application 01

Feeder load switching

The SF6 load break switch body opens and closes load current on overhead distribution feeders, branch circuits, loop points or transformer circuits.

  • Primary switch body
  • 12 / 24 / 36 kV class
  • 400 / 630 A class
Application 02

Optional intelligent operation

Add the LBS controller when the site needs sensing, event records, communication and local or remote operation.

  • Controller cabinet option
  • Current / voltage sensing
  • SCADA or local interface
Application 03

RFQ boundary

The RFQ should state whether the buyer needs only the LRFW switch body or the switch body plus intelligent controller and wiring review.

  • Switch body scope
  • Controller option
  • Drawing review
Engineering drawings

Mounting Drawings, Terminal Fit and Wiring Review.

Use installation, dimensional and wiring drawings to confirm pole mounting, terminal clearance and controller connections before production approval.

Mounting

Single-pole installation reference

Confirm anchor ears, assembly frame, lift handle, hole, nameplate position and controller box location from the installation drawing.

Dimensions

Mounting holes and terminal size

Check outline dimensions, installation hole distance and terminal connection size before production drawings are approved.

Wiring

Controller wiring review

When the intelligent controller is selected, review command, status, power, CT/VT or voltage sensor and communication paths from the wiring drawing.

Single pole installation drawing for pole-mounted SF6 load break switch

Single-pole installation drawing

Check anchor ears, assembly frame, lift handle, nameplate and controller box position before the final drawing is approved.

Dimensional drawings for pole-mounted SF6 load break switch mounting and terminal size

Dimensional drawing

Check outline dimensions, installation hole distance and terminal connection size against the selected voltage class.

Factory documents

Review Files for LRFW Ratings, Controller and Drawings.

LRFW sheets, RPS/PGS comparison material, LBS controller manuals and wiring drawings support different decisions. The page keeps rating data, controller functions and engineering review separate.

Visible rating tableLRFW structure and technical-characteristics sheets.

These files supply the visible 12 / 24 / 36 kV, 400 / 630 A table, service conditions, single-pole installation data and structure list.

Comparison familyRPS / PGS pole-mounted load break switch catalog.

This material lists IEC 62271-103, 6-40.5 kV, 400 / 630 / 800 / 1250 A, 20 kA / 4 s, IP67 and suspended or horizontal mounting. Treat it as a separate series check.

Controller and wiringLBS controller guide and wiring drawings.

These files support phase and ground current sensing, voltage sensing, SCADA ports, AC input, control circuit, power circuit and terminal definitions.

Standards

Check the IEC reference by selected series

The RPS/PGS catalog references IEC 62271-103. One supplied LRFW sheet references IEC 62271-200. Confirm the selected model and buyer standard before making a compliance statement.

Structure

12 named structure points

The sheet identifies lift handle, carrying handle, rubber bushing, manual operation handle, position indicator, support frame, grounding device, locking device, pressure relief device, electric mechanism, pressure gauge and filling valve.

Installation

Single-pole mounting drawing

The installation drawing shows upside and downside anchor ears, assembly frame, controller box position, lift handle, hole and nameplate position.

Environment

Outdoor service conditions

Confirm altitude <=3000 m, -40 deg C to +50 deg C, humidity, wind speed <=34 m/s, icing <10 mm, snow <35 mm and pollution grade III / IV.

Gas system

SF6 pressure and leakage checks

The LRFW table lists SF6 gas as arc-extinction and insulation medium, with SF6 gas yearly leak rate <=0.5%. RPS/PGS comparison data lists a separate <=1% yearly gas leakage reference.

RFQ

Before final quotation

Request the selected series, final nameplate, dimensional drawing, single-pole installation confirmation, wiring diagram, controller settings basis and inspection record.

FAQ

SF6 Load Break Switch Selection FAQ.

What is a pole-mounted SF6 load break switch?

It is an outdoor SF6 insulated load break switch installed on overhead distribution feeders for load current switching, line sectionalizing, loop points and transformer circuit control. The LBS controller is an optional automation package for sensing, alarms, local operation and SCADA communication.

Is it the same as an automatic vacuum circuit recloser?

No. The SF6 LBS is for load current switching and sectionalizing. If the project needs fault-current interruption with automatic reclosing protection, compare the Automatic Vacuum Circuit Recloser.

Which ratings should be confirmed first?

Confirm the selected switch series first, then voltage class, rated current, short-time withstand or breaking requirement, terminal or cable outlet style, operating method, service environment and mounting condition.

Which standards are shown in the source files?

The RPS/PGS catalog references IEC 62271-103. One supplied LRFW sheet references IEC 62271-200. Treat these as source-file notes until the selected model and purchaser standard are confirmed.

What controller interfaces are available?

The controller manual references front-panel operation, PC software and web programming, Ethernet and USB access, plus RS-232, Ethernet and RS-485 ports for SCADA or device interconnection.

What should be sent for quotation?

Send system voltage, rated current, feeder role, short-circuit level, terminal or cable outlet style, mounting method, manual or electric operation, CT/VT sensing, controller or SCADA needs, destination standard, quantity and site drawings or photos.

Quotation rangeUSD 1,200-9,500 reference range

Indicative FOB equipment range for early budgeting. Final quote depends on rating class, controller package, quantity, destination and utility standard.

Line roleLoad switching, sectionalizing and loop-point control

Check the line position before selecting the adjacent Smart Grid product family.

Review filesEngineering files before approval

Switch-body rating, controller package, CT / VT sensing, terminal style and drawings.

RFQ inputOpen the quotation popup

Send drawings, photos, electrical ratings and export requirements through the RFQ form.

Request a Quote With Switch Duty and Controller Scope.

Start with the selected series, voltage class, rated current, short-time level, feeder role, loop or sectionalizing requirement, terminal or cable outlet style, mounting drawing and service environment. Then state whether the RFQ needs the LBS controller cabinet, CT/VT sensing, motor wiring, SCADA interface, quantity and destination. To compare adjacent equipment, return to the Smart Grid equipment hub, review User Boundary Switch or compare the Automatic Vacuum Circuit Recloser. For company background, see About XIYA POWER.