Dark industrial switchgear cabinet lineup concept used as the complete switchgear cabinets hero background
Gas-insulated switchgear

GIS Switchgear for 10 kV, 12 kV and 24 kV Sealed MV Cabinets

XIYA POWER supplies sealed gas-insulated MV switchgear for 10 kV, 12 kV and 24 kV distribution projects, including JLSRM-12 RMU, XRM/SRM common-box cabinets, HXGN15-12 SF6 ring network cabinets and enclosed RMU packages. Share the SLD, module sequence, rated current, short-circuit level, SF6 tank requirement and cable interface so the cabinet option can be matched before drawings and quotation.

10 / 12 / 24 kVSF6 sealed tankC / F / V / CB modules
Series and ratings

10 kV, 12 kV and 24 kV GIS/RMU Models and Ratings

Compare sealed tank format, module sequence, insulation withstand, busbar current, protection level and application environment before requesting drawings.

JLSRM gas-insulated ring main unit cabinet lineup
Gas-insulated RMU

JLSRM-12 Gas-Insulated Ring Main Unit

12 kV gas-insulated RMU for 6 kV and 10 kV distribution systems, using modular C and V units, sealed stainless-steel tank construction and expandable bus options.

12 kV630 A classC and V modules20 kA V module

Fits compact cable ring or distribution-terminal duty where fixed or expandable modular RMU combinations are required.

XRM common-box fully insulated ring main unit lineup
Fully insulated common-box RMU

XRM/SRM 12/24 Common-Box Gas-Insulated Switchgear

Fully insulated and fully sealed common-box switchgear for compact secondary power stations and medium-voltage distribution nodes.

12/24 kVC/F/V/CB modulesSF6 1.4 barGB3906

Fits sealed common-box projects where C, F, V or CB modules must match the utility standard and cable interface.

HXGN15 SF6 ring network cabinet lineup
SF6 ring network cabinet

HXGN15-12 SF6 Ring Network Cabinet

SF6 load-switch-based metal-enclosed ring network cabinet with an air-insulated cabinet structure and automation option.

12/24 kV1250/630 A bus20 kA / 3 sIP3X

Fits compact and expandable ring network cabinets where SF6 load-switch duty and interlocking need to be confirmed.

Gas-insulated ring main unit with outdoor enclosure and open front doors
Outdoor enclosed gas-insulated RMU

Gas-Insulated RMU With Enclosure

Enclosed 10 kV gas-insulated RMU package for cable engineering, commercial centers, industrial parks and dense urban distribution areas.

10 kV networkSF6 gas chamberIP65 chamber20-year maintenance-free design

Fits compact cable distribution points where an enclosed, fully sealed and touchable SF6 gas chamber is required.

Gas-insulated RMU

JLSRM-12 Gas-Insulated Ring Main Unit Specifications

12 kV gas-insulated RMU for 6 kV and 10 kV distribution systems, using modular C and V units, sealed stainless-steel tank construction and expandable bus options.

Application10 kV and 6 kV distribution systems, ring networks and distribution terminals
Rated voltage12 kV
Rated current630 A class; fuse option noted for the matching module
Rated frequency50/60 Hz
Power-frequency withstand voltage45 kV
Lightning impulse withstand voltage75 kV
Transfer current1700 A for C module
Active load and closed-loop breaking current630 A
Cable-charging breaking current50/10 A
Short-circuit breaking current20 kA for V module
Short-circuit making current63 kA peak
Short-time withstand current25/20 kA load/earth switching duty
Peak withstand current63 kA
Mechanical life3000 operations for C module; 10000 operations for V module
Construction notesFixed or expandable modular combinations, sealed stainless-steel body, expandable bus and distribution automation option
StandardsGB standards stated
Fully insulated common-box RMU

XRM/SRM 12/24 Common-Box Gas-Insulated Switchgear Specifications

Fully insulated and fully sealed common-box switchgear for compact secondary power stations and medium-voltage distribution nodes.

ApplicationSecondary power stations, switching stations, industrial sites, railways, high-rise buildings, subways and tunnels
Rated voltage12/24 kV
Module categoriesC load switch; F combination switch; V vacuum switch with isolation/earthing switch; CB vacuum circuit breaker with isolation/earthing switch
Rated currentC 630 A; F 125 A; V 630 A; CB 1250/630 A
Power-frequency withstand42/50 kV
Lightning impulse withstand95/125 kV
Short-time withstandC 25/2; V/ES 20 or 16/3; CB/ES 25 or 20/3 kA/s
Short-circuit breakingF 31.5 kA; V 20/16 kA; CB 25/20 kA
Mechanical lifeC 5000; F 3000; V 5000; ES 2000/5000 operations
SF6 gas pressure1.4 bar
Service temperature-25 C to +40 C
Humidity<95%
StandardsGB3906
Construction notesCompact, fully enclosed, fully insulated and maintenance-free common-box cabinet
SF6 ring network cabinet

HXGN15-12 SF6 Ring Network Cabinet Specifications

SF6 load-switch-based metal-enclosed ring network cabinet with an air-insulated cabinet structure and automation option.

ApplicationUrban distribution, small secondary substations, switching stations, shopping malls, airports, subways, railways and tunnels
Rated voltage12/24 kV
Lightning impulse same/opposite75/125 kV
Lightning impulse between open contacts85/145 kV
Power-frequency same/opposite42/65 kV
Power-frequency between open contacts48/79 kV
Frequency50/60 Hz
Main bus rated current1250/630 A
Branch bus rated current1250/630 A
Short-time main-circuit withstand20 kA / 3 s
Short-time earthing withstand20 kA / 2 s
Peak withstand50 kA
Transfer current1700/800 A
Protection levelIP3X
Load switch mechanical life2000 operations
Earthing switch mechanical life2000 operations
StandardsGB3906
Outdoor enclosed gas-insulated RMU

Gas-Insulated RMU With Enclosure Specifications

Enclosed 10 kV gas-insulated RMU package for cable engineering, commercial centers, industrial parks and dense urban distribution areas.

Application10 kV distribution network cable engineering, commercial centers, industrial parks and dense urban areas
Insulation mediumSF6 gas
Gas chamber protectionIP65
Leakage rateAnnual SF6 leakage rate less than 0.25 per thousand
Service life reference20 years maintenance-free
StructureFully insulated, fully sealed and touchable cable-head wiring structure
Pressure monitoringSF6 pressure gauge and RTU pressure transmission option
AutomationDistribution network automation support
Operation safetyAnti-misoperation function stated for the ring main unit
Environment fitMoisture-proof, corrosion-resistant, compact installation and harsh-environment suitability stated
01

Voltage class

10 / 12 / 24 kV

Confirm whether the project uses a 10 kV cable network, 12 kV gas-insulated RMU or 12/24 kV common-box and SF6 cabinet values.

02

Tank format

Sealed, common-box or enclosed

Separate stainless-steel sealed tank, common-box cabinet, SF6 ring cabinet and outdoor enclosed RMU before drawing release.

03

Module sequence

C / F / V / CB

Define load-switch, fuse-combination, vacuum-switch, circuit-breaker, earthing and metering bays from the single-line diagram.

04

Rated current

125 A / 630 A / 1250 A

Check the current class by module because fuse, load-switch, vacuum-switch and breaker modules do not share one rating.

05

Fault level

20 / 25 / 31.5 kA classes

Match breaking current, making current, short-time withstand and peak withstand to the network calculation.

06

Cable and utility interface

Cable size, IP level and standard

Confirm cable termination, enclosure duty, gas pressure monitoring, room limit and utility acceptance before quotation.

Site conditions

Applications and Service Conditions for Sealed MV Cabinets

Use GIS gas-insulated switchgear where compact sealed MV switching is needed and the project requires SF6, common-box or enclosed gas-insulated cabinet construction.

01

Cable distribution networks

Select gas-insulated cabinets for 10 kV cable engineering, ring networks and distribution terminals where sealed compact switching improves cable distribution reliability.

02

Secondary substations and switching stations

Use JLSRM, XRM/SRM or HXGN15 where compact secondary substations and switching stations need sealed MV switching.

03

Commercial, industrial and dense urban sites

Enclosed gas-insulated RMU packages fit commercial centers, industrial parks and dense urban areas where compact sealed cable distribution is required.

04

Transit and building power rooms

XRM/SRM and HXGN15 application text includes railways, high-rise buildings, subways, tunnels, shopping malls and airports.

Delivery controls

Drawings, Routine Tests and Packing Checks

After the gas-insulated cabinet option, voltage class and module sequence are fixed, confirm drawings, routine checks and packing method before production release. For broader sealed cabinet file review, download GIS switchgear catalog PDFs.

01

General arrangement drawing

Cabinet lineup, module order, sealed tank format, overall dimensions, cable compartment, foundation reference and room clearance.

02

Single-line and control drawings

Incoming and outgoing modules, load switch or breaker function, metering, protection, automation interface and terminal wiring.

03

Routine verification

Power-frequency withstand, insulation, mechanical operation, earthing operation, interlock, nameplate, gas pressure and protection-degree checks.

04

Packing and handling

Cabinet split, lifting point, moisture protection, SF6 sealed-tank handling note, packing marks and destination standard.

What does GIS gas-insulated switchgear mean for this cabinet range?

It refers to sealed MV distribution cabinets using SF6 gas insulation, common-box construction, SF6 ring network cabinet design or enclosed gas-insulated RMU packages. It is not a full substation GIS bay system.

How is GIS gas-insulated switchgear different from a standard RMU?

A standard RMU can be gas-insulated, solid-insulated or SF6 based. The GIS range focuses on sealed gas-insulated and SF6 cabinet construction, tank format, pressure monitoring and utility acceptance.

Which voltage classes are available for GIS gas-insulated switchgear?

Ratings cover 10 kV enclosed gas-insulated RMU applications, 12 kV JLSRM gas-insulated RMU and 12/24 kV XRM/SRM and HXGN15 cabinet values.

What should be checked before choosing C, F, V or CB modules?

Confirm the single-line diagram, load-switch duty, fuse-combination protection, vacuum-switch or breaker duty, earthing switch need, metering bay, cable termination and short-circuit level.

Which standards should be stated in the RFQ?

State the required project standard, such as IEC 62271 series or GB/T 3906 where applicable, plus any utility-specific acceptance rules. XIYA POWER should confirm the standard basis for the selected cabinet before drawing release.

What should be sent for a GIS switchgear quotation?

Send voltage class, single-line diagram, module sequence, rated current, fault level, SF6 or sealed tank requirement, cable size, termination type, metering or automation need, required standard, quantity, destination and Incoterms.

Engineering reviewReviewed July 7, 2026

Reviewed by XIYA POWER sales engineering for JLSRM-12, XRM/SRM 12/24, HXGN15-12 and enclosed gas-insulated RMU selection use.

Selection dataVoltage, module and SF6 tank

Final cabinet choice depends on voltage class, module sequence, sealed tank format, rated current, fault level and cable interface.

DocumentsGA, SLD and control drawings

Production release uses cabinet layout, single-line and control drawings, routine test checklist and packing method.

Quotation ruleProject-based scope

No standard cabinet package is assumed; quotation follows cabinet option, configuration, quantity, destination and Incoterms.

Project-based quotation

Send an SLD for a GIS Switchgear Quote

Send the SLD, voltage class, module sequence, rated current, short-circuit level, SF6 tank or enclosure requirement, cable size and termination type, metering or automation needs, required standard, quantity, destination and Incoterms. XIYA POWER will return the matched cabinet option, rating check, drawing list, packing method and quote basis. For procurement review, check certificates, test reports and RFQ forms.