XIYA POWER supplies sealed gas-insulated MV switchgear for 10 kV, 12 kV and 24 kV distribution projects, including JLSRM-12 RMU, XRM/SRM common-box cabinets, HXGN15-12 SF6 ring network cabinets and enclosed RMU packages. Share the SLD, module sequence, rated current, short-circuit level, SF6 tank requirement and cable interface so the cabinet option can be matched before drawings and quotation.
Compare sealed tank format, module sequence, insulation withstand, busbar current, protection level and application environment before requesting drawings.
Confirm whether the project uses a 10 kV cable network, 12 kV gas-insulated RMU or 12/24 kV common-box and SF6 cabinet values.
Separate stainless-steel sealed tank, common-box cabinet, SF6 ring cabinet and outdoor enclosed RMU before drawing release.
Define load-switch, fuse-combination, vacuum-switch, circuit-breaker, earthing and metering bays from the single-line diagram.
Check the current class by module because fuse, load-switch, vacuum-switch and breaker modules do not share one rating.
Match breaking current, making current, short-time withstand and peak withstand to the network calculation.
Confirm cable termination, enclosure duty, gas pressure monitoring, room limit and utility acceptance before quotation.
Use GIS gas-insulated switchgear where compact sealed MV switching is needed and the project requires SF6, common-box or enclosed gas-insulated cabinet construction.
Select gas-insulated cabinets for 10 kV cable engineering, ring networks and distribution terminals where sealed compact switching improves cable distribution reliability.
Use JLSRM, XRM/SRM or HXGN15 where compact secondary substations and switching stations need sealed MV switching.
Enclosed gas-insulated RMU packages fit commercial centers, industrial parks and dense urban areas where compact sealed cable distribution is required.
XRM/SRM and HXGN15 application text includes railways, high-rise buildings, subways, tunnels, shopping malls and airports.
After the gas-insulated cabinet option, voltage class and module sequence are fixed, confirm drawings, routine checks and packing method before production release. For broader sealed cabinet file review, download GIS switchgear catalog PDFs.
Cabinet lineup, module order, sealed tank format, overall dimensions, cable compartment, foundation reference and room clearance.
Incoming and outgoing modules, load switch or breaker function, metering, protection, automation interface and terminal wiring.
Power-frequency withstand, insulation, mechanical operation, earthing operation, interlock, nameplate, gas pressure and protection-degree checks.
Cabinet split, lifting point, moisture protection, SF6 sealed-tank handling note, packing marks and destination standard.
It refers to sealed MV distribution cabinets using SF6 gas insulation, common-box construction, SF6 ring network cabinet design or enclosed gas-insulated RMU packages. It is not a full substation GIS bay system.
A standard RMU can be gas-insulated, solid-insulated or SF6 based. The GIS range focuses on sealed gas-insulated and SF6 cabinet construction, tank format, pressure monitoring and utility acceptance.
Ratings cover 10 kV enclosed gas-insulated RMU applications, 12 kV JLSRM gas-insulated RMU and 12/24 kV XRM/SRM and HXGN15 cabinet values.
Confirm the single-line diagram, load-switch duty, fuse-combination protection, vacuum-switch or breaker duty, earthing switch need, metering bay, cable termination and short-circuit level.
State the required project standard, such as IEC 62271 series or GB/T 3906 where applicable, plus any utility-specific acceptance rules. XIYA POWER should confirm the standard basis for the selected cabinet before drawing release.
Send voltage class, single-line diagram, module sequence, rated current, fault level, SF6 or sealed tank requirement, cable size, termination type, metering or automation need, required standard, quantity, destination and Incoterms.
Reviewed by XIYA POWER sales engineering for JLSRM-12, XRM/SRM 12/24, HXGN15-12 and enclosed gas-insulated RMU selection use.
Final cabinet choice depends on voltage class, module sequence, sealed tank format, rated current, fault level and cable interface.
Production release uses cabinet layout, single-line and control drawings, routine test checklist and packing method.
No standard cabinet package is assumed; quotation follows cabinet option, configuration, quantity, destination and Incoterms.
Send the SLD, voltage class, module sequence, rated current, short-circuit level, SF6 tank or enclosure requirement, cable size and termination type, metering or automation needs, required standard, quantity, destination and Incoterms. XIYA POWER will return the matched cabinet option, rating check, drawing list, packing method and quote basis. For procurement review, check certificates, test reports and RFQ forms.